Chapter 4 Assembly
75
Table 4.3-1 User control options for the unit using the PC/DS-L2
PC DS-L2
Unit
Control Status Control Status
Brightness
control dial
Notes
EXTERNAL:
ON (external
mode)
Lamp lit/unlit,
lamp brightness
adjustment
Lamp lit/unlit,
lamp brightness
adjustment
/
Lamp lit/unlit,
lamp brightness
adjustment
/ ---
LV-LH50 PC
Lamphouse
EXTERNAL:
OFF
(internal
mode)
/
Lamp lit/unlit,
lamp brightness
adjustment
/
Lamp lit/unlit,
lamp brightness
adjustment
Lamp lit/unlit,
lamp brightness
adjustment
---
C-HGFI HG Precentered
Fiber Illuminator
/ / / / /
Do not use the C-HGFI when
the LV-NU5A motorized
nosepiece is mounted.
C-HGFIE HG Precentered
Fiber Illuminator
Changing the
shutter
open/close, ND
(Neutral
Density)
1
Shutter
open/close, ND
(Neutral
Density)
/
2
Shutter
open/close, ND
(Neutral
Density)
/
To connect the C-HGFIE with
the MA200 main body, use
the RS232C cross cable.
When attaching the C-HGFIE
to the microscope with the
LV-NU5A motorized
nosepiece mounted, RS232C
cross cable must be used for
their connection to control the
shutter according to the
rotation of the motorized
nosepiece. If you fail to make
this connection, a fire of light
may enter in the view-field at
the rotation of the motorized
nosepiece.
Light source
MA2-DP supporting pillar
for dia-Illuminator 100W
/ / / / /
To use the MA2-DP for the
diascopic illumination, set the
brightness control dial to OFF.
LV-NU5A motorized
nosepiece
Rotation of the
revolving
nosepiece
3
Address for the
revolving
nosepiece
Rotation of the
revolving
nosepiece
3
Address for the
revolving
nosepiece
Connect the Motorized
Nosepiece Controller 2 with
the MA200 main body using
the RS232C cross cable.
MA2-NUI5 revolving
nosepiece
/
Address for the
revolving
nosepiece
/
Address for the
revolving
nosepiece
---
D-ND6 revolving nosepiece /
Address for the
revolving
nosepiece
/
Address for the
revolving
nosepiece
---
Revolving nosepiece
D-NI7 revolving nosepiece /
Address for the
revolving
nosepiece
/
Address for the
revolving
nosepiece
---
Intermediate
magnification
MA2-MC intermediate
magnification unit
/
Magnification of
the MA2-MC
/
Magnification of
the MA2-MC
---
Objective
information
Registering information on
the objective
Objective info Objective info / Objective info
Refer to “4.3.3 Registering
information on the objective.”
1: Shutter open/close or ND select can be controlled using the remote controller (C-HGFIE-C HG controller) exclusive for the C-HGFIE.
2: The shutter open/close or ND select can be controlled if the remote controller (C-HGFIE-C HG controller) exclusive for the C-HGFIE
is used.
3: The rotation of the revolving nosepiece can be controlled on the Motorized Nosepiece Controller 2.